INPUT CHARACTERISTICS: |
|
|
VOLTAGE:
90 ~ 264 VAC FULL RANGE |
|
|
FREQUENCY:
47 - 63 Hz |
|
|
INPUT
CURRENT:
7.0 A ( RMS ) FOR 115 VAC
3.5 A ( RMS ) FOR 230 VAC |
|
|
INRUSH
CURRENT:
55A MAX. FOR 115 VAC
110A MAX. FOR 230 VAC |
| >
SPECIFICATION |
|
|
TEMPERATURE
RANGE : OPERATING 0oC --- 40oC |
|
|
HOLD
UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT
VOLTAGE |
|
|
DIELECTRIC
WITHSTAND:
INPUT / OUTPUT 1500 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND |
|
|
EFFICIENCY:
71% TYPICAL |
|
|
POWER
GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms |
|
|
OVER
LOAD PROTECTION: 130 +/- 20%
OVER VOLTAGE PROTECTION:
+5V 5.7
~ 6.5V, 3.3V 3.9
~ 4.3V, 12V 13.6
~15V
SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V
UNDER VOLTAGE PROTECTION:
+5V 4.1V
~ 4.5V, 3.3V 2.69
~ 2.97V, 12V 9.8
~10.8V
OVER CURRECT PROTECTION: 3.3V, 5V, 12V,-5V,-12V,5VSB
EMI : FCC CLASS B, CISPR22 CLASS B |
|
|
SAFETY:
UL 1950, CSA 22.2 NO/ 950, TUV IEC 950 |
|
|
REMOTE
ON / OFF CONTROL
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH
WILL DISABLE / ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE
+5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE. |
|
|
3.3V
/ 5V REMOTE SENSING |
|
|
COOLING:
ONE 60mm DC FAN |
|
|
DIMENSION:
240 (D) x 100 (W) x 70 (H) mm |
|
|
MEET
IEC-1000-3-2 CLASS D (ACTIVE PFC, PF:0.98 ) |